카테고리 보관물: Microscope

GX53

GX53

Quickly Analyze Thick, Large Sample Materials

Designed for use in the steel, automotive, electronics, and other manufacturing industries, the GX53 microscope delivers crisp images that can be difficult to capture using conventional microscopy observation methods. When combined with OLYMPUS Stream image analysis software, the microscope streamlines the inspection process from observation to image analysis and reporting.

Fast Inspections, Advanced Functionality

Quickly observe, measure, and analyze metallurgical structures.

Advanced Analysis Tools

1. Combined observation methods produce exceptional images

2. Easily create panoramic images

3. Create all-in-focus images

4. Capture both bright and dark areas

Optimized for Material Science

1. Software designed for materials science

2. Metallurgical analysis that complies with industrial standards

Userfriendly

Even novice operators can comfortably make observations, analyze results, and create reports.

1. Easily restore microscope settings

2. User guidance helps simplify advanced analysis

3. Efficient report generation

Advanced Imaging Technology

Our proven optics and imaging technology deliver clear images and reliable results.

1. Reliable optical performance: wavefront aberration control

2. Clear images: image shading correction

3. Consistent color temperature: high-intensity white LED illumination

4. Precise measurements: auto calibration

Modular

Choose the components you need for your application.

1. Build your system your way: fully customizable system with a variety of optional components

MX63/MX63L

EVIDENT – MX63 / MX63L

Streamline Your Large Sample Inspection Workflow

The MX63 and MX63L microscope systems are optimized for high-quality inspections of wafers as large as 300 mm, flat panel displays, circuit boards, and other large samples. Their modular design enables you to choose the components you need to tailor the system to your application.

These ergonomic and user-friendly microscopes help increase throughput while keeping inspectors comfortable while they do their work. Combined with OLYMPUS Stream image analysis software, your entire workflow, from observation to report creation, can be simplified.


Functional

Leading-Edge Analysis Tools

The MX63 series’ versatile observation capabilities provide clear, sharp images so users can reliably detect defects in their samples. New illumination techniques and image acquisition options within OLYMPUS Stream image analysis software give users more choices for evaluating their samples and documenting their findings.


The Invisible Becomes Visible: MIX Observation and acquisition

MIX observation technology produces unique observation images by combining darkfield with another observation method, such as brightfield, fluorescence, or polarization. MIX observation enables users to view defects that are difficult to see with conventional microscopes. The circular LED illuminator used for darkfield observation has a directional darkfield function where only one quadrant is illuminated at a given time. This reduces a sample’s halation and is useful for visualizing a sample’s surface texture.

Structure on semiconductor wafer

Condenser


Easily Create Panoramic Images: Instant MIA

With multiple image alignment (MIA), users can stitch images together quickly and easily simply by moving the KY knobs on the manual stage—a motorized stage is not necessary. OLYMPUS Stream software uses pattern recognition to generate a panoramic image, giving users a wider field of view.

Instant MIA image of a coin


Create all-in-focus images: EFI

The Extended Focus Imaging (EFI) function within OLYMPUS Stream captures images of samples whose height extends beyond the depth of focus of the objective and stacks them together to create one image that is all in focus. EFI can be executed with either a manual or motorized Z-axis and creates a height map for easy structure visualization. It is also possible to construct an EFI image while offline within Stream Desktop.

Stud bump on an IC chip


Capture Both Bright and Dark Areas Using HDR

Using advanced image processing, high dynamic range (HDR) adjusts for differences in brightness within an image to reduce glare. HDR improves the visual quality of digital images thereby helping to generate professional-looking reports.


From Basic Measurement to Advanced Analysis

Measurement is essential to quality and process control and inspection. With this in mind, even the entry-level OLYMPUS Stream software package includes a full menu of interactive measurement functions, with all measurement results saved with image files for further documentation. In addition, the OLYMPUS Stream Materials Solution offers an intuitive, workflow-oriented interface for complex image analysis. At the click of a button, image analysis tasks can be executed quickly and precisely. With a significant reduction in processing time for repeated tasks, operators can concentrate on the inspection at hand.


Efficient Report Creation

Creating a report can often take longer than capturing the image and taking the measurements. OLYMPUS Stream software provides intuitive report creation to repeatedly produce smart and sophisticated reports based on pre-defined templates. Editing is simple and reports can be exported to Microsoft Word or PowerPoint software. In addition, OLYMPUS Stream software’s reporting function enables digital zooming and magnification on acquired images. Report files are a reasonable size for easier data exchange by email.


Stand-Alone Camera Option

Using a DP22 or DP27 microscope camera, the MX63 series becomes an advanced stand-alone system. The cameras can be controlled via a compact box that requires only minimal space, helping users maximize their laboratory space while still capturing clear images and making basic measurements.


Advanced Designed to Support Cleanroom Conformity

The MX63 series is designed to work in a cleanroom and has features that help minimize the risk of contaminating or damaging samples. The system has an ergonomic design that helps keep users comfortable, even during prolonged use. The MX63 series complies with international specifications and standards, including SEMI S2/S8, CE, and UL.

Optional Wafer Loader Integration ― AL120 System*

An optional wafer loader can be attached to MX63 series to safely transfer both silicon and compound semiconductor wafers from a cassette to the microscope stage without using tweezers or wands. Renowned performance and reliability enable safe, efficient front and back macro inspections while the loader helps improve productivity in the laboratory.

MX63 combined with the AL120 wafer loader (200 mm version)

Fast, Clean Inspections

The MX63 series delivers contamination-free wafer inspections. All motorized components are housed in a shielded structure, and antistatic processing is applied to the microscope frame, tubes, breath shield, and other parts. The rotation speed of the motorized nosepieces is faster and safer than manual nosepieces, decreasing the time between inspections while keeping the operator’s hands below the wafer, reducing potential contamination.


System Design Achieving Efficient Observations

The XY stage is capable of both coarse and fine stage movements thanks to the combination of a built-in clutch and the XY knobs. The stage helps make observations efficient, even for large samples, such as 300 mm wafers.
The tilting observation tube’s extensive range enables operators to sit at the microscope in a comfortable posture.


System Design Achieving Efficient Observations

The XY stage is capable of both coarse and fine stage movements thanks to the combination of a built-in clutch and the XY knobs. The stage helps make observations efficient, even for large samples, such as 300 mm wafers.
The tilting observation tube’s extensive range enables operators to sit at the microscope in a comfortable posture.


Accepts All Wafer Sizes

Wafer holders and glass plates

The system works with various types of 150–200 mm and 200–300 mm wafer holders and glass plates. Should the size of the wafters change on the production line, the microscope’s frame can be modified at minimal cost. With the MX63 series, different stages can be used to accommodate 75 mm, 100 mm, 125 mm, and 150 mm wafers on the inspection line.


JNO-G(L)

JNOPTIC Filter JNO-G(L)

Download Catalog _ JNO-G(L)

– Filter set for TRITC / Cy3 Longpass
– Chroma Filter Model No. : 19004

JNO-G(L) Spectrum

JNO-G(L)
Standard Green Excitaion filter (Long Pass type)
FiltersType
AT540/25xEX
AT565DCBS
AT575lpEM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

* TRITC VS JNO-G(L)


JNO-G(L)필터를 이용한 Sample Image 촬영

JNO-G(L)를 사용하여 보는 TRITC 형광 이미지
Filter Set : JNO-G(L)
Camera : AcquCAM 23GR2
C-mount adapter : 1x
Lens : UPLAPO40X
Sample : bovine pulmonary artery endothelial cell, BPAEC
JNO-G(L)를 사용하여 보는 TRITC 형광 이미지
Filter Set : JNO-G(L)
Camera : AcquCAM 5G
C-mount adapter : 1x
Lens : UPLAPO40X
Sample : bovine pulmonary artery endothelial cell, BPAEC
JNO-G(L)를 사용하여 보는 TRITC 형광 이미지
Filter Set : JNO-G(L) Camera : AcquCAM 3G C-mount adapter : 1x Lens : UPLAPO40X Sample : bovine pulmonary artery endothelial cell, BPAEC

JNO-G(L)필터에 적합한 형광색소

  • TRITC
  • Cy3
  • R-phycoerythrin

JNO-G(L) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than 26x38mm, please contact us for pricing.

JNO-B(L)

JNOPTIC Filter JNO-B(L)

Download Catalog _ JNO-B(L)

– Filter set for GFP / FITC Longpass
– Chroma Filter Model No. : 19002

JNO-B(L) Spectrum

Blue Excitation, Long Pass Emission
JNO-B(L) Spectrum
FiltersType
AT480/30xEX
 AT505DCBS
AT515lpEM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

 * FITC VS JNO-B(L)

FITC VS JNO-B(L)

 * GFP VS JNO-B(L)

GFP VS JNO-B(L)
GFP VS JNO-B(L)

JNO-B(L)필터를 이용한 Sample Image 촬영

Sample : bovine pulmonary artery endothelial cell, BPAEC Filter Set : JNO-B(L) Camera : AcquCAM 23GR2 C-mount adapter : 1X Lens : UPLNAPO40X
AcquCAM 3G BX51 UPlanApo40x JNO-B(L) 1X
Sample : bovine pulmonary artery endothelial cell, BPAEC Filter Set : JNO-B(L) Camera : AcquCAM 3G C-mount adapter : 1X Lens : UPLNAPO40X
Fluorescence Image by AcquCAM 5G
Sample : bovine pulmonary artery endothelial cell, BPAEC Filter Set : JNO-B(L) Camera : AcquCAM 5G C-mount adapter : 1X Lens : UPLNAPO40X

JNO-B(L)필터에 적합한 형광색소

  • Acridine Orange + DNA and RNA
  • Auramine-rhodamine
  • JC-1 non-ratiometric

JNO-B(L) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than 26x38mm, please contact us for pricing.

JNO-U(L)

Download Catalog _ JNO-U(L)

– Filter set for UV/DAPI Longpass
– Chroma Filter Model No. : 19000

JNO-U(L) Spectrum

JNO-U(L) Spectrum
FiltersType
AT375/28xEX
AT415DCBS
AT435lpEM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

* DAPI VS JNO-U(L)

DAPI VS JNO-U(L)

JNO-U(L)필터를 이용한 Sample Image 촬영

DAPI
Sample : bovine pulmonary artery endothelial cell, BPAEC
Lens : UPLNAPO40X, C-mount adapter : 1X
Camera : AcquCAM 23GR2, Filter Set : JNO-U(L)
DAPI
Sample : bovine pulmonary artery endothelial cell, BPAEC
Lens : UPLNAPO40X, C-mount adapter : 1X
Camera : AcquCAM 23S2, Filter Set : JNO-U(L)
DAPI
Sample : bovine pulmonary artery endothelial cell, BPAEC
Lens : UPLNAPO40X, C-mount adapter : 1X
Camera : AcquCAM 3G, Filter Set : JNO-U(L)
DAPI
Sample : bovine pulmonary artery endothelial cell, BPAEC
Lens : UPLNAPO40X, C-mount adapter : 1X
Camera : AcquCAM 5G, Filter Set : JNO-U(L)

JNO-U(L)에 적합한 형광색소

  • Calcofluor White
  • DAPI

JNO-U(L) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than 26x38mm, please contact us for pricing.

JNO-R1(B)

JNOPTIC Filter JNO-R1(B)

Download Catalog_JNO-R1(B)

– Filter set for Texas Red / mCherry / AlexaFluor 594
– Chroma Filter Model No. : 39010

JNO-R1(B) Spectrum

JNO-R1(B)
JNO-R1(B)
FiltersType
AT560/40xEX
AT600DCBS
AT635/60mEM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

Texas Red VS JNO-R1(B)
Texas Red VS JNO-R1(B)
mCherry VS JNO-R1(B)
mCherry VS JNO-R1(B)
Alexa Fluor 594 VS JNO-R1(B)
Alexa Fluor 594 VS JNO-R1(B)

JNO-R1(B)필터에 적합한 형광색소


JNO-R1(B) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than 26x38mm, please contact us for pricing.

JNO-G(B)

JNOPTIC Filter JNO-G(B)

Download Catalog _ JNO-G(B)

– Filter set for TRITC / Cy3 / TagRFP / AlexaFluor546
– Chroma Filter Model No. : 39004

JNO-G(B) Spectrum

JNO-G(B)
Standard Green Excitaion filter (Bans Pass type)
FiltersType
AT540/25xEX
AT565DCBS
AT605/55mEM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

* TRITC VS JNO-G(B)

TRITC VS JNO-G(B) Spetctrum Data
TRITC에 사용했을때 JNO-G(B)

 * Cy3 VS JNO-G(B)

 * AlexaFluor546 VS JNO-G(B)

JNO-G(B) VS AF594
AF594에 사용되는 JNO-G(B)의 스펙트럼 비교

JNO-G(B)필터를 이용한 Sample Image 촬영

JNO-G(B)를 사용하여 보는 TRITC 형광 이미지
Filter Set : JNO-G(B)
Camera : AcquCAM 3G
C-mount adapter : 1x
Lens : UPLAPO20X
Sample : bovine pulmonary artery endothelial cell, BPAEC
대체 텍스트
Filter Set : JNO-G(B)
Camera : AcquCAM 5G
C-mount adapter : 1x
Lens : UPLAPO40X
Sample : bovine pulmonary artery endothelial cell, BPAEC
JNO-G(B)를 사용하여 보는 TRITC 형광 이미지
Filter Set : JNO-G(B)
Camera : AcquCAM 23GR2
C-mount adapter : 1x
Lens : UPLAPO20X
Sample : bovine pulmonary artery endothelial cell, BPAEC

JNO-G(B)필터에 적합한 형광색소


JNO-G(B) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than 26x38mm, please contact us for pricing.

JNO-B(B)

JNOPTIC Filter JNO-B(B)

Download Catalog _ JNO-B(B)

– Filter set for EGFP / FITC / Cy2 / AlexaFluor488
– Chroma Filter Model No. : 39002

JNO-B(B) Spectrum

FiltersType
AT480/30xEX
 AT505DCBS
AT535/40mEM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

* FITC VS JNO-B(B)

FITC VS JNO-B(B)

 * GFP VS JNO-B(B)

JNO-B(B) VS GFP spectrum 비교
JNO-B(B) VS GFP spectrum chart

 * AlexaFluor488 VS JNO-B(B)

JNO-B(B) VS AlexaFluor 488
JNO-B(B) VS AlexaFluor 488

JNO-B(B)필터를 이용한 Sample Image 촬영

Fluorescence Image by AcquCAM 23GR2
Sample : bovine pulmonary artery endothelial cell, BPAEC Filter Set : JNO-B(B) Camera : AcquCAM 23GR2 C-mount adapter : 1X Lens : PlanApo60xWLSM
Fluorescence Image by AcquCAM 3G
Sample : bovine pulmonary artery endothelial cell, BPAEC Filter Set : JNO-B(B) Camera : AcquCAM 3G C-mount adapter : 1X Lens : PlanApo60xWLSM
Fluorescence Image by AcquCAM 5G
Sample : bovine pulmonary artery endothelial cell, BPAEC Filter Set : JNO-B(B) Camera : AcquCAM 5G C-mount adapter : 1X Lens : UPLNAPO40X

JNO-B(B)필터에 적합한 형광색소


JNO-B(B) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than 26x38mm, please contact us for pricing. ( Tel. 02-3473-4188)

JNO-U(B)

Download Catalog _ JNO-U(B)

– Filter set for DAPI / Hoechst / AlexaFluor350
– Chroma Filter Model No. : 39000

JNO-U(B) Spectrum

JNO-U(B)
Filters Type
 AT375/28x EX
AT415DC BS
 AT460/50m EM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

* DAPI VS JNO-U(B)

DAPI VS JNO-U(B)

* Hoechst VS JNO-U(B)

JNO-U(B) VS Hoechst

 * AlexaFluor350 VS JNO-U(B)

JNO-U(B) VS AF350

JNO-U(B)필터를 이용한 Sample Image 촬영

DAPI
Sample : bovine pulmonary artery endothelial cell, BPAEC
Camera : AcquCAM 23GR2, Filter Set : JNO-U(B)
Objective lens : UPLNAPO40X, C-mount adapter : 1X
AcquCAM 23GR2 fluorescence Image
DAPI, FITC, TRITC
Sample : bovine pulmonary artery endothelial cell, BPAEC
Camera : AcquCAM 23GR2, Filter Set : JNO-U(B),B(B),G(B)
Objective lens : UPLNAPO40X, C-mount adapter : 1X (OLYMPUS)
Above three images are merged and processed using JNO-ARM
DAPI, FITC, TRITC
Sample : bovine pulmonary artery endothelial cell, BPAEC
Camera : AcquCAM 3G, Filter Set : JNO-U(B),B(B),G(B)
Objective lens : UPLNAPO40X, C-mount adapter : 1X
Above three images are merged and processed using JNO-ARM

JNO-U(B) 필터에 적합한 형광색소

JNO-U(B) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than *** 26x38mm, please contact us for pricing.